Polimaster Innovating radiation detection technologies since 1992
EN

Gamma Personal Radiation Detector PM1401MA

Category: Gamma PRDs

Personal radiation detector PM1401MA is designed for detecting of gamma radiation sources. Due to its hermetic and shockproof case and the LCD screen fluorescent backlight, instrument can be used in extreme and harsh environments. For work in difficult-to-access areas telescopic extension tube is provided. PRD has audible, visual and vibrating alarms, records and stores up to 1000 events in non-volatile memory and transmits data to a PC via IR channel.

PM1401MA is recommended for first responders, security guards, police, customs officers and border patrol. No special experience or training is necessary to operate the instrument.

Learn more

Operation Principle

Once the PRD is turned on, it automatically starts taking measurements and storing the background radiation information. Instrument can detect the slightest increase in the radiation background. The instruments advanced processing algorithm enables the user to update the background levels and setup the alarm thresholds depending on the probability and false alarm rate requirements. Detector is able to detect radiation sources when the background decreases due to radiation shielding or when the background radiation intensity is high requiring the source to be located among high radiation level.

Application

  • Inspection of Raw Materials, Waste & Goods
  • Inspection of Raw Materials, Waste & Goods

Standards Compliance

Designed to meet ANSI N42.32-2006, ANSI N42.33 -2006, IEC 62401:2007, ITRAP+10 (IAEA) requirements

Complies with ANSI 42.32-2016

Specifications

Detector Csl(TI) scintillator
Sensitivity, gamma radiation:
137Cs 100 s-1/(µSv/h) / (1 s-1/(µR/h))
241Am 100 s-1/(µSv/h) / (1 s-1/(µR/h))
Energy range 0.06 – 3.0 MeV
Dose equivalent rate (DER) measurement range 0.1 µSv/h – 70 µSv/h / (10 µR/h – 7000 µR/h)
DER measurement accuracy ±(20+1/Ḣ)%, where Ḣ = DER, μSv/h
DER indication range 0.01 µSv/h – 99.99 µSv/h / (1 µR/h – 9999 µR/h)
Response time:
0.25 s
Alarm Type visual, audible and external vibrator
Power supply one AA size battery
Battery lifetime:
up to 1000 hours
PC communication IR interface
Data recording 990 data points
Ingress protection IP65
Dimensions 110х57х32 mm (41/3 х 21/4 х 11/4 in)
Weight 320 g. (11.29 oz) - including battery
Drop test on concrete floor 1.5 m (5 ft.) onto concrete surface
Operating temperature -30°C to 50°C (-22°F to 122°F); LCD -15 to +50 °C (+5 to +122,5 °F )
Humidity up to 95 % at +35 °C (+95 °F )

Support

Software:

PM PRD software (1401, 1703, 1703MO-2) ver. 17.2, 17.09.2014 (English, Russian)
Size : 8.12 MB

Advertising:

PM1401MA Leaflet
Size : 1.20 MB

Software User Manuals:

PM PRD Software User Guide
Size : 273.16 KB

Related products

Personal Combined Radiation Detector/Dosimeter PM1703MO-1BT
Personal Combined Radiation Detector/Dosimeter PM1703MO-1BT Learn more
Personal Radiation Detector PM1703MA-II
Personal Radiation Detector PM1703MA-II Learn more
Personal Radiation Detector PM1703GNA-II
Personal Radiation Detector PM1703GNA-II Learn more
Personal Radiation Detector PM1703GNA-II BT
Personal Radiation Detector PM1703GNA-II BT Learn more

Contacts

E-mail:

polimaster@polimaster.com

Site:

en.polimaster.com