PM1703MO-1 combines features of both Personal Radiation Detector and Dosimeter. Instrument is equipped with two detection modules: highly sensitive CsI(Tl) scintillation detector and small-sized GM tube detector. CsI(Tl) scintillation detector allows to search radioactive and nuclear materials and GM tube detector allows to measure dose rate of gamma radiation in the wide energy range. Instrument has non-volatile memory, audible, visual and vibration alarms, shockproof hermetic case, compact size and light weight, user-friendly interface and doesn`t require special knowledge or training of personnel. Due to compact size, user can wear PRD on the utility belt.

PM1703MO-1/PM1703MO-1BT are recommended for customs and border guards, personnel of nuclear power plants, isotope laboratories, first responders, firefighters, military, police, etc.  

Learn more

Operation Principle

PM1703MO series combine functionality of both Personal Radiation Detector and Dosimeter. Instruments measure ambient dose equivalent rate and ambient dose equivalent of gamma and X-ray radiation, search radioactive materials and alert user with audible, visual and vibration alarms. All operation history is stored in the instruments non-volatile memory, protecting the data even when the battery is removed. The stored data can be transferred to a personal computer via infrared interface or Bluetooth (PM1703MO-1BT modification).

PM1703MO-1BT Modification

Modification PM1703MO-1BT is equipped with Bluetooth v 4.0 Low Energy Module (BLE112) and can exchange data with user’s mobile device in real time. Mobile apps (for iOS and Android) can be downloaded from the App StoreSM or from Google PlayTM.

Additional

Instruments can be equipped with the additional registration modes of specific activity and surface activity of the 134Cs, 137Cs radionuclides in different samples, such as food, drinking water, different liquids, crumbling construction materials, soil, etc. by special order.

Application

  • Access Control
  • Illicit Trafficking of Nuclear and Radioactive Materials
  • Inspection of Raw Materials, Waste & Goods
  • Emergency Response
  • Inspection of Raw Materials, Waste & Goods
  • Radiation Security of Public Events & Sites

Standards Compliance

Designed to meet ANSI N42.33 -2006, IEC 62401:2007, IEC 60846-1:2009, ITRAP+10 (IAEA) requirements

Complies with ANSI 42.32-2016

Specifications

Detector CsI(Tl), GM tube
Dose equivalent rate (DER) measurement range from 0.1 µSv/h to 9.99 Sv/h
DER indication range from 0.01 µSv/h to 9.99 Sv/h
DER measurement accuracy ±(20+K1/Ḣ+K2·Ḣ)%, where Ḣ – DER value, mSv/h; K1 – coefficient 0.0025 mSv/h; K2 – coefficient 0.002 (mSv/h)-1
Dose equivalent (DE) measurement range from 0.1 µSv to 9.99 Sv
DE indication range from 0.01 µSv to 9.99 Sv
DE measurement accuracy ± 20 %
Sensitivity, gamma radiation: for 241Am in search mode for 137Сs in search mode 100 cps/(µSv/h)
85 cps/(µSv/h)
Energy response relative to 0.662 MeV: ± 30 %
Energy range: in DER measurement mode in search mode from 0.06 to 1.33 MeV
from 0.033 to 3.0 MeV
Alarm Type audible, vibration, light
PC communication IR
Power supply AA (LR6) battery (Alkaline) 1.5 V, min. 2000 mA/h or rechargeable battery AA (R6) (Ni-MH (Nickel Metal Hydride)) 1,5 V, min. 1900 mA/h
Battery lifetime: at average ambient background 0.3 µSv/h, LCD backlight, audible and vibration alarms 5 min/24 hours 1000 h
Dimensions 72 x 32 x 87 mm (2 13/16" x 1 ¼" x 3 7/16")
Weight 250 g (including battery)
Drop test on concrete floor 0.7 m onto concrete
Ingress protection IP65
Operating temperature -30 to +50°С (LCD indication from -20 to +50°С)
Humidity up to 98 % at 35°С
Atmospheric pressure 84 to 106.7 kPa

Support

Software:

PM1703MO-1 Software ver.1.0.4.1, 04.11.16 (English,Russian)
Size : 93.78 MB
PM1703MO-1 User Software ver.1.3.31.1 (04.01.2018) (USA)
Size : 70.29 MB

Advertising:

PM1703MO-1/MO-1BT Leaflet
Size : 813.38 KB

Software User Manuals:

PM1703MO-1 software user guide
Size : 1.26 MB

Certificates

PM1703MO-1 CE Certificate Download

Related products

Gamma Personal Radiation Detector PM1401MA Learn more
Personal Radiation Detector PM1703M Learn more
Mobile Radiological Laboratory PM6000 Learn more
Personal Radiation Detector PM1703MA Learn more

Contacts

E-mail:

polimaster@polimaster.com

Site:

en.polimaster.com