Polimaster Innovating radiation detection technologies since 1992
RU

Fixed Portal Monitor PM5000C-01H

Category: Transport RPMs

Fixed Portal Monitors of PM5000C Series are designed in a lightweight body and have compact dimensions, increased degree of body protection and high sensitivity. Fixed portal monitors can be installed at the facilities that use or produce radioactive materials, at customs and border checkpoints, major highways, bridges etc.

Learn more

Operation Principle

Fixed portal monitors of PM5000C Series are configured as one multipurpose gamma/neutron radiation detector module. RPMs have modular design and may have one-pillar or two-pillar configurations, adaptable height and width according to customer requirements. Monitors can be equipped with video monitoring system upon customer request.

Modifications

  • PM5000C-01H - two-pillar gamma monitor with 4 gamma detector modules;
  • PM5000C-05H – two-pillar gamma monitor with 2 gamma radiation detector modules with enlarged volume for increased sensitivity;
  • PM5000C-10H - two-pillar gamma neutron monitor with 4 gamma-neutron radiation detector modules with enlarged volume for increased sensitivity;
  • PM5000C-14 - two-pillar neutron monitor with 4 neutron detector modules.

Advantages

  • Compact dimensions
  • Lightweight body
  • Increased sensitivity

 

Application

  • Inspection of Raw Materials, Waste & Goods
  • Inspection of Raw Materials, Waste & Goods

Standards Compliance

Designed to meet ANSI N42.35 - 2006 , ITRAP+10 (IAEA) requirements

Specifications

Number of detection units 4
Type of registered radiation gamma
Energy range 0.03 - 3 MeV
Ingress protection IP55
Minimum detectable amounts of radioactive materials, control zone 6 x 4 m.:
241Am, MBq, (µCi); speed 8 km/h. 1.8 (49)
137Cs, MBq, (µCi); speed 8 km/h. 0.21 (5.7)
60Co, MBq, (µCi); speed 8 km/h. 0.12 (3.2)
238U, g; speed 8 km/h. 1300
235U, g; speed 8 km/h. 80
239Pu,g; speed 8 km/h. 2.3
Minimum detectable amounts of radioactive materials, control zone 6 x 4 m.:
241Am, MBq, (µCi); speed 20 km/h. 2.7 (71)
137Cs, MBq, (µCi); speed 20 km/h. 0.31 (8.4)
60Co, MBq, (µCi); speed 20 km/h. 0.17 (4.6)
238U, g; speed 20 km/h. 1900
235U, g; speed 20 km/h. 120
239Pu,g; speed 20 km/h. 2.4
Power:
external 90-260V AC 50/60Hz
internal battery (12V) with minimum 8 hours lifetime after external power failure
Weight one detector - 75 kg.
Operating temperature - 30 up to +50 °C
Humidity up to 100%
Atmospheric pressure from 84 up to 106,7

Related products

Radiation Monitor PM5000B-01
Radiation Monitor PM5000B-01 Learn more
Radiation Monitor PM5000B-09
Radiation Monitor PM5000B-09 Learn more
Radiation Monitor PM5000B-10
Radiation Monitor PM5000B-10 Learn more

Contacts

E-mail:

polimaster@polimaster.com

Site:

en.polimaster.com