Polimaster Innovating radiation detection technologies since 1992
EN

Radiation Monitor PM5000B-05

Category: Transport RPMs

Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.

Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.

Learn more

Operation Principle

RPMs have modular design and may have one-pillar or two-pillar configurations, adaptable height and width according to customer requirements. Monitors can be equipped with video monitoring system.

Key Features

  • High sensitivity
  • Advanced data processing algorithms
  • Modular design
  • Easy-in-use
  • Audible and light alarms
  • Indoor and outdoor installations
  • Reliable, automatic, 24/7 operation
  • PC connection through the Ethernet port
  • Video monitoring system (option)
  • Integration into a nuclear protection network  controlled by a central PC (option) with further integration into higher level networks controlled by an Expert Center (option)

Modifications

  • РМ5000В-01 - two-pillar gamma monitor with 4 gamma radiation detector modules;
  • РМ5000В-05 - two-pillar gamma monitor with 2 gamma radiation detector modules;
  • РМ5000В-09 - two-pillar gamma-neutron monitor with 2 gamma-neutron radiation detector modules on 10B / ZnS (Ag) basis;
  • РМ5000В-10 - two-pillar gamma-neutron monitor with 4 gamma and 4 neutron radiation detector modules on 10B / ZnS (Ag) basis;
  • РМ5000В-13 - two-pillar neutron monitor with 2 neutron detector modules on 10B / ZnS (Ag) basis;
  • РМ5000В-14 - two-pillar neutron monitor with 4 neutron detector modules on 10B / ZnS (Ag) basis;
  • РМ5000В-16 - two-pillar gamma monitor which consists of 8 gamma radiation detector modules;

Monitored objects:

  • Cars
  • Pedestrians
  • Luggage

Application

  • Access Control
  • Illicit Trafficking of Nuclear and Radioactive Materials
  • Inspection of Raw Materials, Waste & Goods
  • Inspection of Raw Materials, Waste & Goods
  • Radiation Security of Public Events & Sites

Standards Compliance

Designed to meet ANSI N42.35 - 2006 , ITRAP+10 (IAEA) requirements

Specifications

Type of registered radiation gamma
Energy range 0.02 to 3.0 MeV
Ingress protection IP65
Number of detection units 2 detectors
Minimum detectable quantities of radioactive materials, control zone 3 x 2 m.:
241Am, MBq, (µCi); speed 5 km/h. 0.62 (17)
137Cs, MBq, (µCi); speed 5 km/h. 0.065 (1.8)
60Co, MBq, (µCi); speed 5 km/h. 0.040 (1.1)
238U, g; speed 5 km/h. 460
235U, g; speed 5 km/h. 32
239Pu,g; speed 5 km/h. 0.9
57Co, MBq (µCi); speed 5 km/h. 0.085 (2.3)
133Ba, MBq (µCi); speed 5 km/h. 0.040 (1.1)
Minimum detectable quantities of radioactive materials, control zone 6 x 2 m.:
241Am, MBq, (µCi); speed 8 km/h. 2.15 (58)
137Cs, MBq, (µCi); speed 8 km/h. 0.23 (6.2)
60Co, MBq, (µCi); speed 8 km/h. 0.145 (3.9)
238U, g; speed 8 km/h. 1800
235U, g; speed 8 km/h. 110
239Pu,g; speed 8 km/h. 3.2
57Co, MBq (µCi); speed 8 km/h. 0.29 (7.8)
133Ba, MBq (µCi); speed 8 km/h. 0.145 (3.9)
Power:
industrial AC network (115-230V range) 47/63 Hz frequency
built-in accumulator battery 12 V DC (back-up). Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours).
Power consumption:
no more then 120 V•А.
Mean time between failures no less then 10000 hours
Mean service lifetime no less then 8 years
Mean recovery time no more then 60 min
Weight one gamma detector – 120 kg; control unit - 20 kg
Operating temperature -30 up to +50°C
Humidity up to 98 % at 40°C and lower, no moisture
Atmospheric pressure from 84 to 106.7 kPa

Video

Contacts

E-mail:

polimaster@polimaster.com

Site:

en.polimaster.com